CAC Seko Pumps

2 min read

INSTALL & USE MANUAL 2025
CIRCUL-AIR SEKO PUMPS

NOTE-for explanations that include images please open the attached file.

For Models:
CAC-SEKO1
CAC-SEKO1
CAC-SEKO3

Abstract: Circul-Air SEKO Pump Manual (Models CAC-SEKO1 / CAC-SEKO3) #

Product: Circul-Air SEKO Chemical Dosing Pumps
Models: CAC-SEKO1, CAC-SEKO2, CAC-SEKO3
Manual Revision: June 23, 2025
Use Category: Chemical Auto-Dosing System for Gear Extractors


Overview #

The SEKO pump system is a programmable chemical dosing unit designed for integration with Circul-Air washer-extractors. It supports liquid or solid detergent injection, delay timing, lock-out, and optional level alarms to ensure accurate and consistent chemical metering for NFPA 1851-aligned decontamination cycles.


Technical Specifications #

  • Power Supply: 115 / 208 / 230 VAC, 50/60 Hz
  • Power Consumption: 14W
  • Fuse: 315 mA @ 250V (5×20 type)
  • Protection Class: Water-resistant gasketed enclosure with internal electronic shielding

Control System Features #

  • Dual independent pumps or solenoids
  • Delay timer: 0 to 5 minutes (individually programmable)
  • Lock-out timer: Up to 75 minutes via dip switch
  • LED status indicators (calibration, delay, lockout, alarm)
  • Remote trigger-ready with 20–230 VAC signal input
  • Manual override “Start Dosing” button with disable option

Installation & Setup #

  • Wall-mount bracket and hardware included
  • Supports 7/16” OD tubing for chemical input/output
  • Powder/solid detergent option supported via water solenoid feeder integration
  • Jumper-based configuration for calibration and lockout timing
  • Optional level float switch input

Calibration Mode #

  • Enter by closing “TYPE” jumper
  • Dispense into a measuring cup to set exact chemical volume
  • Default dosing time: 1 second
  • System exits calibration when jumper is removed

Maintenance Routine #

  • Replace squeeze tubes regularly
  • Clean pump heads and replace worn tubing
  • Inspect foot filters for debris
  • Maintain voltage integrity to prevent dosing variation

Troubleshooting Snapshot #

  • Power issues: Check fuse and incoming voltage
  • No pump output: Verify motor wiring and clear obstructions
  • Over/under dosing: Recalibrate and check for clogs or probe faults

Use Case Fit #

  • Designed for integration with all Circul-Air Extractors
  • Compatible with both liquid (CitroSqueeze®) and solid chemistries
  • Ideal for stations standardizing detergent volumes across wash cycles